The ALTIVAR 58 (ATV58) family of adjustable frequency AC drive controllers is all the parameters detailed in this manual will be accessible if a drive controller. User’s Manual for the Altivar 58F and for the I/O . 1 Follow the recommendations in the User’s Manual supplied with the speed controller, most importantly. ALTIVARĀ® 58 (ATV58) AC drive controllers offer superior performance in a compact .. A GV2 manual motor starter, ATV58 drive controller, and an output.

Author: Fezragore Voktilar
Country: Rwanda
Language: English (Spanish)
Genre: Education
Published (Last): 28 April 2006
Pages: 372
PDF File Size: 15.16 Mb
ePub File Size: 1.59 Mb
ISBN: 724-8-72249-159-9
Downloads: 65436
Price: Free* [*Free Regsitration Required]
Uploader: Kazrak

The commands are combinations of the 5 mandatory bits. If a logic input assigned to the local force function is set to 1: The bits ayv58 the control register CMD have the following meaning: These documents should be referred to for hardware and software setup as well as for any variables specific to each bus. We also recommend consulting manua, of the Altivar 58 programming guides for additional explanations operation, factory settings, etc.

The speed controller status can at5v8 modified by sending a control word CMD or by the occurrence of an mwnual example: It comes with the specific documentation supplied with: The “Internal Variables” User’s manual defines the variable speed controller control process using the serial link as well as the internal variables for the speed controller which are common to the various types of bus.

  CATALOGO RUBBERMAID 2009 PDF

The speed controller status is given by the value of the status register ETA. DC injection stop H’F’: Communication principle The Altivar 58 can be connected to two fieldbuses: Each state represents an aspect of the internal behaviour of the speed controller.

The bus controlling the speed controller can relinquish control by setting bits 8 and 15 of the control word CMD to 1. The fieldbus connected to the communication card always takes priority.

However, the fieldbus which is not controlling the speed controller may send configuration words only when the motor is stopped or adjustments, and read signalling words. The local forcing output must be monitored, as line control is restored at the current chart step at the moment of interrupt caused by local forcing. Manuao chart below has been adapted to the characteristics of the Altivar 58 to facilitate programming.

User’s manual FIPIO ATV58 : VW3A | Schneider Electric

Their description can in no way beconsidered contractual. The products described in this document may be changed or modified at any time, either froma technical point of view or in the way they are operated.

  EL HIPNOTISTA LARS KEPLER DESCARGAR PDF

Type of stop Corresponding Manuxl for restoring control Drivecom state of the Altivar 58 using the fieldbus Freewheel stop “ATV58 powered up” – set the logic input assigned to the “freewheel stop” function to 1 – perform the transitions required to return the speed controller to “run” status Fast stop “ATV58 running” – set the logic input assigned to the mwnual stop” function to 1 DC injection stop “ATV58 running” – set the logic input assigned to the “injection stop” function to 1 Stop via keypad “ATV58 powered up” – release Stop key STOP key – perform the transitions required to return the speed controller to “run” status 3-wire control “ATV58 powered up” – set the logic input assigned to stop via logic input STOP to 1 STOP LI1 – perform the transitions required to return the speed controller to “run” status Local forcing: In local forcing all write requests from the fieldbus are refused.

For safety reasons its use must be restricted to the debug phase.